Glossary
Every abbreviation and acronym of the industrial world — automation, fieldbuses, functional safety, ATEX, OT/IT cybersecurity, AI, networking, process and sustainability. Instant search by acronym or keyword.
139 acronyms defined · 11 categories
No result.
Automation 14
APC Advanced Process Control Advanced process control. Includes MPC, complex cascades, real-time optimization. A layer above DCS.
CMMS Computerized Maintenance Management System Maintenance management software (SAP PM, Maximo, Coswin). Work order tracking, preventive plans, history.
DCS Distributed Control System Distributed control system for continuous, I/O-heavy processes. Redundant architecture, integrated engineering.
ERP Enterprise Resource Planning Enterprise management information system (SAP, Oracle, Microsoft Dynamics). Purdue level 5.
HMI Human-Machine Interface Operator interface — panel, screen or web. ISA-101 best practice: gray dominant, color reserved for abnormal.
IED Intelligent Electronic Device Protection relay or intelligent electronic device in electrical substations. Target of IEC 61850.
IIoT Industrial Internet of Things Industrial Internet of Things: connected sensors, edge computing, cloud platforms, MQTT Sparkplug, OPC UA.
MES Manufacturing Execution System Manufacturing execution system between ERP and DCS/PLC. Traceability, scheduling, recipe management (ISA-95).
MPC Model Predictive Control Predictive control based on a dynamic process model. Anticipates and optimizes over an N-step horizon.
OEE Overall Equipment Effectiveness Universal productivity KPI = Availability × Performance × Quality.
PID Proportional-Integral-Derivative Classic feedback controller combining three terms (proportional, integral, derivative) for control loops.
PLC Programmable Logic Controller Industrial automation controller with deterministic scan cycle and IEC 61131-3 languages (LD, FBD, ST, SFC). Core of discrete automation.
RTU Remote Terminal Unit Remote telemetry and control unit using DNP3 or IEC 60870-5. Typical in wide-area SCADA networks.
SCADA Supervisory Control and Data Acquisition Wide-area supervision and acquisition (water, energy, gas, rail). Remote RTU/PLC polling, historian, alarm management.
Buses & protocols 14
APL Advanced Physical Layer (Ethernet-APL) Two-wire Ethernet + power physical layer for ATEX zone 0/1. Natural successor of PROFIBUS PA / FF H1.
AS-i Actuator Sensor Interface Low-cost binary bus for on/off sensors and actuators. Yellow flat vampire-tap cable, mixed power and signal.
CAN Controller Area Network Differential serial bus originally for automotive (Bosch 1986). Foundation of industrial CANopen and DeviceNet.
DNP3 Distributed Network Protocol 3 Dominant North American SCADA protocol for electricity and water. IEEE 1815. RTU-side time-stamping, event classes.
EtherCAT Ethernet for Control Automation Technology Ultra-fast Industrial Ethernet (Beckhoff/ETG). On-the-fly circulating frame, <100 µs latency. High-performance motion control.
FF H1 Foundation Fieldbus H1 Two-wire process bus (FieldComm) for ATEX zone 1 instrumentation. Direct competitor of PROFIBUS PA.
HART Highway Addressable Remote Transducer Protocol overlaying digital signal on the analog 4-20 mA loop. Sensor configuration without changing wiring.
IO-Link IO-Link (IEC 61131-9) Intelligent single-drop link between sensor/actuator and master. Power + measurement + diagnostic + parameterization on the same wires.
Modbus Modbus protocol Grandfather of industrial protocols (Modicon, 1979). RTU (serial) and TCP (IP) variants. Universal and simple.
MQTT Message Queuing Telemetry Transport Ultra-light publish/subscribe protocol. Industrial Sparkplug B variant for IIoT cloud (auto-discovery, rich metadata).
OPC UA OPC Unified Architecture IT/OT interoperability standard (IEC 62541). Rich information model, native security (Sign + Encrypt + X.509).
PROFIBUS Process Field Bus RS-485 serial bus. DP version (Decentralized Periphery) for distributed I/O, PA version for ATEX process instrumentation.
PROFINET Process Field Net Deterministic Industrial Ethernet driven by Siemens / PI. Dominant in Europe. Classes: Standard, RT, IRT.
TSN Time-Sensitive Networking Set of Ethernet extensions (IEEE 802.1) making standard Ethernet deterministic. Convergence layer of future buses.
Functional safety 20
BMS Burner Management System Burner management system — safe ignition sequence, flame supervision, fault shutdown. NFPA 85, EN 12952/12953.
DC Diagnostic Coverage Diagnostic Coverage. Fraction of dangerous failures detected by automatic internal diagnostics.
ESD Emergency Shutdown Emergency shutdown of a process. ESD system = SIS dedicated to rapid shutdown to safe state.
FIT Failure In Time Failures per 10⁹ hours. Standard unit on component datasheets.
FMECA Failure Mode, Effects and Criticality Analysis Systematic analysis of failure modes, their effects and their criticality. Risk analysis tool.
HAZOP Hazard and Operability Study Systematic study of hazards and operability. Word-by-word analysis (More, Less, No, Reverse…) of deviations.
HFT Hardware Fault Tolerance Hardware Fault Tolerance. HFT = 1: the function is preserved despite one failure (1oo2, 1oo2D, 2oo3 architectures).
LOPA Layer of Protection Analysis Layer of Protection Analysis. Quantifies risk reduction by each IPL (Independent Protection Layer) to derive required SIL.
MOC Management of Change Management of Change. Formal process to track, assess and approve any safety-impacting change. IEC 61511 requirement.
MTBF Mean Time Between Failures Mean Time Between Failures. MTBF (h) = 10⁹ / FIT. Statistical — does not guarantee individual lifetime.
MTTR Mean Time To Repair Mean Time To Repair. Directly affects PFD (shorter MTTR reduces simultaneous unavailability probability).
PFD Probability of Failure on Demand Probability of failure on demand (low-demand mode). SIL 2: 10⁻³ ≤ PFD < 10⁻². See also PFDavg.
PFDavg Average Probability of Failure on Demand PFD averaged over the proof-test interval T1. IEC 61508 reference metric in low-demand mode.
PFH Probability of dangerous Failure per Hour Probability of dangerous failure per hour (high-demand / continuous mode). SIL 2: 10⁻⁷ ≤ PFH < 10⁻⁶.
RRF Risk Reduction Factor Risk Reduction Factor = 1 / PFD. How much the safety function divides the residual risk.
SFF Safe Failure Fraction Safe Failure Fraction = (λSU + λSD + λDD) / λtot. Share of safe or detected failures.
SFRT Safety Function Response Time Total response time of the safety function — sensor to actuator in safe state. Must be shorter than the process safety time.
SIF Safety Instrumented Function Safety Instrumented Function — a specific safe-state action (e.g. burner trip on flame failure).
SIL Safety Integrity Level Safety Integrity Level (IEC 61508 / 61511). 4 levels: SIL 1 (lowest) to SIL 4 (most stringent).
SIS Safety Instrumented System Safety Instrumented System. Sensors + logic solver + final elements realising one or more SIFs.
ATEX / Ex 10
AIT Auto-Ignition Temperature Auto-ignition temperature. Temperature at which a mixture self-ignites without spark. Basis of T1-T6 classes.
ATEX ATmosphères EXplosibles European regulatory framework for explosive atmospheres. Directive 2014/34/EU (equipment) + 99/92/EC (workplaces).
EPL Equipment Protection Level Equipment Protection Level. Ma/Mb (mining), Ga/Gb/Gc (gas), Da/Db/Dc (dust). Determines permitted zone.
IECEx IEC System for Certification of Explosive Atmospheres IEC international scheme. Mutual recognition of Ex certifications between test labs (ExTL) and certification bodies (ExCB).
IK Impact Protection (IEC 62262) Mechanical impact resistance rating. IK00 (none) to IK10 (20 J). Complements IP.
IP Ingress Protection (IEC 60529) Ingress Protection rating. Two digits: 1st = solids (0-6), 2nd = liquids (0-9). E.g. IP65 = dust-tight + water jets.
IS Intrinsic Safety Intrinsic safety (Ex i, IEC 60079-11). Energy in the circuit limited below ignition threshold even on fault.
LEL Lower Explosive Limit Lower Explosive Limit. Minimum fuel concentration in air below which no explosion is possible.
MIE Minimum Ignition Energy Minimum Ignition Energy of a gas/air or dust/air mixture. Hydrogen: ~0.02 mJ; methane: ~0.28 mJ.
UEL Upper Explosive Limit Upper Explosive Limit. Maximum concentration above which the mixture is too rich to explode.
Cybersecurity 21
ANSSI Agence nationale de la sécurité des systèmes d'information French national cybersecurity authority. EBIOS RM framework, PASSI/PDIS qualifications, OIV oversight.
CRA Cyber Resilience Act EU regulation on products with digital elements. Applicable end 2027. Security-by-design, 5 years of updates.
DORA Digital Operational Resilience Act EU Regulation 2022/2554. Digital operational resilience for the financial sector. Applicable since Jan 2025.
EDR Endpoint Detection and Response Successor of antivirus. Endpoint agent, behavioural analysis, MITRE ATT&CK detection. CrowdStrike, SentinelOne, Microsoft Defender.
IACS Industrial Automation and Control System Official IEC 62443 term for industrial automation and control system as a whole.
IAM Identity and Access Management Identity and Access Management. Okta, Microsoft Entra (formerly Azure AD), Ping. SSO, MFA, entitlement governance.
ICS Industrial Control System Industrial Control System — generic term covering PLC, DCS, SCADA. Near-synonym of IACS.
IDS Intrusion Detection System Intrusion detection system. In OT, passive sensors (Dragos, Nozomi, Claroty CTD) analysing ICS traffic.
IT Information Technology Enterprise IT — workstations, servers, cloud, applications, data. Distinct from OT.
MFA Multi-Factor Authentication Multi-factor authentication: something I know + something I have + something I am. TOTP, FIDO2, badges.
NDR Network Detection and Response Detection and response based on network traffic analysis (vs EDR on endpoints). Essential in OT.
NIS2 Network and Information Security Directive 2 EU Directive 2022/2555. Cybersecurity for essential and important entities. Transposed Oct 2024. Fines up to €10M or 2% turnover.
OT Operational Technology Operational Technology — PLCs, DCS, SCADA, sensors. As opposed to IT (information technology).
PAM Privileged Access Management Privileged Access Management. Password vault + recorded sessions. CyberArk, Wallix, BeyondTrust, Thycotic.
PKI Public Key Infrastructure Public Key Infrastructure. Generates, signs and manages X.509 certificates. Microsoft AD CS, HashiCorp Vault, EJBCA.
RGPD Règlement Général sur la Protection des Données (GDPR) EU Regulation 2016/679. Personal data protection. Fines up to 4% of global turnover or €20M.
SIEM Security Information and Event Management Security log collection and correlation. Splunk, Microsoft Sentinel, Elastic, Wazuh, Graylog.
SOAR Security Orchestration, Automation and Response Security orchestration and automated incident response. Palo Alto XSOAR, Splunk SOAR, Tines.
SOC Security Operations Center Security Operations Center. Human team + SIEM/SOAR/EDR tools running 24/7 to detect and respond.
SSO Single Sign-On Single Sign-On. One authentication grants access to multiple applications. SAML, OIDC, Kerberos.
XDR Extended Detection and Response Extended EDR aggregating endpoint + network + cloud + email for unified correlation.
AI 12
AI Artificial Intelligence Artificial intelligence. Includes machine learning, deep learning, generative AI, symbolic expert systems.
DL Deep Learning Deep Learning. ML based on multi-layer neural networks. Vision, NLP, audio.
EU AI Act EU Artificial Intelligence Act EU Regulation 2024/1689. First worldwide AI regulatory framework. Risk-based (unacceptable / high / limited / minimal).
GenAI Generative AI Generative AI. Capable of producing original content (text, code, image, diagram). Used industrially for PLC copilots.
GPAI General-Purpose AI General-Purpose AI. Category defined by the EU AI Act for models with broad capabilities (mainly LLMs). Specific obligations.
LLM Large Language Model Large Language Model. GPT, Claude, Gemini, Mistral, Llama. Foundation of copilots and GenAI.
ML Machine Learning Machine Learning. Statistical models that learn from data rather than being explicitly programmed.
MLOps Machine Learning Operations DevOps for ML. Model lifecycle: training, edge deployment, monitoring, drift detection, retraining.
NIST AI RMF NIST AI Risk Management Framework NIST AI Risk Management Framework. 4 functions: Govern, Map, Measure, Manage. Published January 2023.
NLP Natural Language Processing Natural Language Processing. Extraction, classification, text generation. Foundation of LLMs.
ONNX Open Neural Network Exchange Open ML model exchange format. Lets you deploy a PyTorch/TensorFlow-trained model on any ONNX runtime (edge included).
RAG Retrieval Augmented Generation Pattern combining an LLM with an indexed document base. Model queries the base before answering. Reduces hallucinations.
Network 11
APN Access Point Name Cellular access point name. A private APN separates corporate mobile traffic from Internet — direct egress to group VPN.
BGP Border Gateway Protocol Inter-domain routing protocol of the Internet. Exchanges routes between autonomous systems (AS).
DMZ Demilitarized Zone Demilitarized Zone. Intermediate subnet between IT and OT. Purdue level 3.5: proxy, jump server, NDR sensors.
MPLS Multiprotocol Label Switching Label switching used by telco operators. SLA-guaranteed, stable latency. Expensive.
NAT Network Address Translation Network Address Translation. Lets multiple private hosts share a single public IP.
SD-WAN Software-Defined WAN Software-defined WAN. Aggregates MPLS, Internet, 4G/5G with automatic failover. Cisco Viptela, Fortinet, Versa.
TCP Transmission Control Protocol Reliable transport protocol of the Internet. Connection, ordering, retransmission. Base of OPC UA, Modbus TCP, HTTPS.
UDP User Datagram Protocol Connectionless Internet transport protocol. Lightweight, no delivery guarantee. Used by DNS, SNMP, optional MQTT.
VLAN Virtual Local Area Network Virtual LAN. Logical segmentation on a switch (IEEE 802.1Q). Does NOT replace a firewall for security.
VPN Virtual Private Network Encrypted tunnel between two networks or user and network. IPsec, OpenVPN, WireGuard, SSL VPN.
ZTNA Zero Trust Network Access Zero Trust Network Access. VPN successor — continuous verification of every access, regardless of perimeter.
Process 8
BPCS Basic Process Control System Basic Process Control System (vs SIS). Standard DCS or PLC. IEC 61511 §3.2.13.
FAT Factory Acceptance Test Factory Acceptance Test. System testing at the manufacturer before delivery. Paired with on-site SAT.
P&ID Piping and Instrumentation Diagram Piping and Instrumentation Diagram. Shows equipment, lines, instruments, valves. ISO 10628, ISA-5.1.
PFD (procédé) Process Flow Diagram Process Flow Diagram. Simplified diagram showing major equipment and flows. NOT to be confused with safety PFD.
PHA Process Hazard Analysis Process Hazard Analysis. Includes HAZOP, what-if, LOPA. Regulatory requirement (OSHA PSM, Seveso).
PRV Pressure Relief Valve Pressure Relief Valve (progressive opening). Often used interchangeably with PSV.
PSV Pressure Safety Valve Pressure Safety Valve (pop-action). Overpressure protection. ASME VIII, EN ISO 4126.
SAT Site Acceptance Test Site Acceptance Test. Final verification after installation and connection, before commissioning.
Project 11
CE Conformité Européenne CE marking. Conformity with European directives for market placement. Self-declaration by manufacturer.
DRP Disaster Recovery Plan Disaster Recovery Plan. Technical procedures to restore service after major incident. Complements the BCP.
GLP Good Laboratory Practice Good Laboratory Practice. OECD framework for regulated laboratory studies.
GMP Good Manufacturing Practice Good Manufacturing Practice. Mandatory pharma framework (EU GMP, US FDA 21 CFR Part 211, 21 CFR Part 11 on electronic records).
KPI Key Performance Indicator Key Performance Indicator. Quantitative measure for steering and evaluation.
MVP Minimum Viable Product Minimum Viable Product. Simplest version already delivering value, to be enriched later.
OEM Original Equipment Manufacturer Original Equipment Manufacturer. Designer and builder of an equipment, vs integrators or resellers.
POC Proof of Concept Proof of concept. Small-scale prototype demonstrating that a technical idea works, before full deployment.
PoT Proof of Test Backtest on historical data. Before a live POC, validation on 12-24 months of past data.
SLA Service Level Agreement Service Level Agreement. Contractual commitment on service quality (availability, response time).
UKCA UK Conformity Assessed Post-Brexit marking for the UK market (England, Wales, Scotland). Coexists with CE for Northern Ireland.
Sustainability 12
CBAM Carbon Border Adjustment Mechanism Carbon Border Adjustment Mechanism. Reporting since Oct 2023, payment from 2026. Steel, aluminium, cement, fertilizers, H₂, electricity.
CCUS Carbon Capture, Utilization and Storage Carbon capture, utilization and storage. Post-combustion, oxy-fuel, geological sequestration, valorization (e-fuels, carbonation).
CEE Certificats d'Économies d'Énergie French white certificates scheme. Obligation on energy suppliers. Funds 10-80% of eligible energy efficiency projects.
CSRD Corporate Sustainability Reporting Directive EU Directive 2022/2464. Mandatory sustainability reporting for ~50,000 EU companies from 2024.
EED Energy Efficiency Directive EU Directive 2023/1791 (recast). EU target 11.7% energy consumption reduction by 2030. Mandatory audit for large companies.
EnPI Energy Performance Indicator Energy Performance Indicator. Normalized metric for energy efficiency monitoring (ISO 50006). E.g. kWh/tonne produced.
ESG Environmental, Social, Governance Environmental, Social and Governance criteria used by investors for sustainability assessment.
ESRS European Sustainability Reporting Standards European Sustainability Reporting Standards. 12 standards adopted by Delegated Regulation 2023/2772 under CSRD.
EU ETS EU Emissions Trading System EU Emissions Trading System. CO₂ market for installations >20 MW thermal. Current price ~€80/tCO₂.
GHG Greenhouse Gas Protocol International carbon accounting framework. Defines scopes 1, 2, 3 used worldwide for GHG reporting.
PPA Power Purchase Agreement Long-term Power Purchase Agreement (10-20 yr) with a renewable producer. Locks price and guarantees of origin.
SBTi Science Based Targets initiative Voluntary initiative validating that corporate emission reduction trajectories are +1.5 °C-aligned. SDA methodology.
Economics 6
CAPEX Capital Expenditure Capital expenditure: money spent once to acquire a durable asset (machines, controllers, construction). Depreciated over its life.
LCOE Levelized Cost of Energy Levelized cost of energy: average cost of an MWh over a plant's whole life (CAPEX + OPEX). Compares solar, wind, gas, nuclear on one basis.
OPEX Operational Expenditure Operational expenditure: money spent continuously to run an asset (energy, maintenance, staff, consumables). Recurring.
ROI Return On Investment Return on investment: gain relative to the outlay, as a percentage. With payback time, it judges a project's profitability.
TCO Total Cost of Ownership Total cost of ownership across the full life cycle: purchase, operation, maintenance, end of life. The real basis to compare two solutions.
TOTEX Total Expenditure Total expenditure = CAPEX + OPEX. A neutral view between buying and operating, used notably in regulated network industries.